-
Oxidative stress and premature senescence in corneal endothelium following pe...
Abstract Background The purpose of this study was to address the question of how the premature senescence process may affect corneal endothelium after penetrating keratoplasty,... -
Quantitative evaluation of corneal epithelial edema after cataract surgery us...
Abstract Purpose The optical density of the cornea can be evaluated quantitatively by “densitometry” using a rotating Scheimpflug camera. Densitometry allows evaluation of... -
Minification of fundus optical coherence tomographic images in gas-filled eye
Abstract Background Optical coherence tomography (OCT) is being used increasingly to evaluate and manage a variety of retinal diseases, but not much is known about the... -
High-resolution dual-modality photoacoustic ocular imaging
We have developed a prototype ocular imaging system that integrates optical-resolution photoacoustic microscopy and high-frequency ultrasound imaging. The system can perform... -
Patient reported outcome measures for visual impairment after stroke: a syste...
Abstract Purpose The aim of this review was to identify patient reported outcome measures (PROMs) for use in research and clinical practice involving individuals with visual... -
Optical coherence tomography features of retinal lesions in Chinese patients ...
Abstract Background To evaluate the optical coherence tomography (OCT) features of retinal lesions in Chinese patients with endogenous Candida endophthalmitis (ECE). Methods We... -
Comparability of three intraocular pressure measurement: iCare pro rebound, n...
Abstract Background Measurement of intraocular pressure (IOP) is essential for glaucoma patients. Many factors such as central corneal thickness (CCT) can affect the accuracy of... -
En-face optical coherence tomography - a novel application of non-invasive im...
Optical Coherence Tomography (OCT) is an optical interferometric technique developed mainly for in vivo imaging of the eye and biological tissues. In this paper, we demonstrate... -
OCT proves that vitreomacular adhesion is significantly more likely to develo...
Abstract Background SD-OCT is becoming commonplace in everyday practice. Vitreomacular adhesions (VMAs) are being more routinely diagnosed. Predictive studies to the natural... -
Long segment 3D double inversion recovery (DIR) hypersignal on MRI in glaucom...
Abstract Background In this retrospective study the relationship between intraocular pressure (IOP), retinal nerve fiber layer (RNFL) thickness and pathologic hypersignal in... -
Changes in corneal thickness following combined cataract and vitreous surgery
Abstract Background We investigated changes in corneal thickness following combined cataract and vitreous surgery and determined whether such changes could be used as a... -
Optical coherence tomography angiography characteristics of acute retinal art...
Abstract Background To characterize the vascular changes in eyes within the acute phase of retinal arterial occlusion (RAO) by optical coherence tomography angiography (OCT-A)... -
Polarization-sensitive swept-source optical coherence tomography with continu...
We present fiber-based polarization-sensitive swept-source optical coherence tomography (SS-OCT) based on continuous source polarization modulation. The light source is a... -
Internal limiting membrane peeling and gas tamponade for myopic foveoschisis:...
Abstract Background Myopic foveoschisis (MF) is among the leading causes of visual loss in high myopia. However, it remains controversial whether internal limiting membrane... -
Noninvasive multimodal imaging in diagnosing polypoidal choroidal vasculopathy
Abstract Purpose To investigate the diagnostic accuracy of noninvasive multimodal imaging methods in diagnosing polypoidal choroidal vasculopathy (PCV) and distinguishing PCV... -
3D nondestructive testing system with an affordable multiple reference optica...
Optical coherence tomography (OCT) is emerging as a powerful noncontact imaging technique, allowing high-quality cross-sectional imaging of scattering specimens... -
Segmentation error in spectral domain optical coherence tomography measures o...
Abstract Background Optical Coherence Tomography (OCT) imaging is being increasingly used in clinical practice for the monitoring of papilloedema. The aim is to characterise the... -
Dermascope guided multiple reference optical coherence tomography
In this paper, we report the feasibility of integrating a novel low cost optical coherence tomography (OCT) system with a dermascope for point-of-care applications. The proposed... -
Postural effects on intraocular pressure and ocular perfusion pressure in pat...
Abstract Background To investigate postural effects on intraocular pressure (IOP) and ocular perfusion pressure (OPP) in patients with non-arteritic ischemic optic neuropathy... -
Minimal internal limiting membrane peeling with ILM flap technique for idiopa...
Abstract Background Internal limiting membrane (ILM) peeling increases the idiopathic macular hole (IMH) closure rate but causes the inner retina dimplings. This study is to...